I am already customer

If you already have an account, please login with your credentials


Forgot password?

Are you a new customer?
Register Now

By creating an account, you can make the purchase and access other services

Create an Account

R23 reclaimed Kryon® 23 in T-PED cylinder 14 Lt - 9,08 Kg (high pressure rented cylinder, deposit Euro 150,00 applies)


R23 rigenerato Kryon® 23 in Bombola 14 Lt - 9,08 Kg a rendere (bombola alta pressione, si applica deposito cauzionale Euro 150,00) - Foto 1
R23 rigenerato Kryon® 23 in Bombola 14 Lt - 9,08 Kg a rendere (bombola alta pressione, si applica deposito cauzionale Euro 150,00) - Foto 2

Request a personalized quote
Contact us for a customized proposal.
image
image
image
    14800 IPCC
Following new
Fgas Reg. (EU) 2024/573

Temperature Range

image
Share:

Very limited availability – please contact our customer service in advance at sales@generalgas.it

R-23: the refrigerant for ultra-low temperatures

R-23 is a non-ozone-depleting azeotropic HFC refrigerant used in refrigeration systems operating at ultra-low temperatures (from -60°C to -100°C). It is suitable for both new systems and as a retrofit replacement in legacy systems operating with HCFC R-13 and R-503. R-23 is used exclusively in cascade systems, with evaporation temperatures between -60°C and -100°C and condensation temperatures between -10°C and -40°C. Its thermodynamic properties closely resemble those of R-13.

Applications:

  • Industrial cooling systems
  • Pharmaceutical production plants
  • Medical use (e.g. blood banks)
  • Material testing
  • Cryomats and cryostats
  • High vacuum

Regarding the refrigerant charge, the same parameters used for the replaced products (HCFC R-13 and R-503) can be applied, provided the expansion vessel is replaced with a larger one. The optimal refrigerant charge is between -10% and -20% compared to that of R-13 and R-503. Thanks to its azeotropic nature, it can be topped up directly in the event of refrigerant leaks from the system. The cooling capacity of R-23 is higher than that of R-13 and lower than that of R-503. In terms of energy efficiency, it is equivalent to R-13 and approximately 10% lower than R-503. Due to its very high GWP value, R-23 will be subject to significant restrictions as a result of the progressive implementation of European F-Gas Regulation No. 517/2014.

Lubricants:

R-23 is compatible with POE synthetic lubricants.

Signup or Signin for Download

Material Safety Data Sheet Signup or Signin for Download
Enthalpy–entropy chart Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.

Other Formats