I am already customer

If you already have an account, please login with your credentials


Forgot password?

Are you a new customer?
Register Now

By creating an account, you can make the purchase and access other services

Create an Account

R456A - T-PED returnable cylinder 13 Lt - 12 kg - drop-in and go replacement to R134a in Automotive air Conditioning


R456A in Bombola a Rendere 13 Lt - 12 Kg - sostituto drop-in del 134a nel condizionamento auto - Foto 1
R456A in Bombola a Rendere 13 Lt - 12 Kg - sostituto drop-in del 134a nel condizionamento auto - Foto 2

RFQ for large quantities
(minimum 10 pcs)
Need to buy large quantities? Contact us for a customized proposal.
image
image
image
    687 (626)
    IPCC AR4 (AR5)

Temperature Range

image
Share:

R456A was designed to extend the availability of R-134a in automotive MVAC while providing a cooling capacity boost for older vehicles.

R456A is a drop-in and go replacement, no oil changes or other changes are required.

Since R456A utilizes a HFO refrigerant (R-1234ze), vehicle service can utilize a value added up sale of Shrieve’s Zerol HFO additive.

R456A lowers the GWP of the R-134a system by over 50% (from GWP 1,430 to GWP 687) giving regulators peace of mind that the existing R-134a fleet will “age out” gracefully.

Benefits:

  • Drop-in capability in R-134a auto
  • Same efficiency as R-134a • Up to a 10% cooling capacity boost
  • Non-flammable – easy conversion, same safety classification as R-134a
  • Over 50% reduction in GWP – good news for future availability to service R-134a fleets
  • Ability to up-sale by co-selling with value added solutions for HFO refrigerants

Application:

R456A is an ASHRAE A1 classified refrigerant (same as R-134a) that was tailored to be a drop-in replacement for R-134a in automotive air conditioning.

It shares the same energy efficiency (fuel consumption) that the vehicle was designed for by the automaker. When used as a complete replacement, by removing all R-134a and replacing with pure R456A, the cooling capacity of the vehicle is increased by approximately 10% which gives a faster cool down in the hot summer months.

However, in service it is not necessary to do a complete replacement of R-134a. Operators can top off a system with R456A or when pulled into a RRR service machine can be mixed in any proportion with R-134a.

It is advisable to label the system as containing R456A, but if a user wants to move back to R-134a this flexibility is left to the professional service garage without any special considerations.

Signup or Signin for Download

Data sheet Signup or Signin for Download
Material Safety Data Sheet Signup or Signin for Download
TEXA Certification Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.

Other Formats